Add lightning protection to the power distribution box in the computer room

Add lightning protection to the power distribution box in the computer room

The power distribution box of the computer room should be equipped with SPD (anti-electromagnetic surge) protection devices to prevent the power supply of the computer room from being cut off due to electromagnetic pulses caused by lightning strikes. Our light-ning and surge voltage protection systems are per-fectly matched to one another and to the requirements in the different zones – from the air-termination device, which must arrest the full energy of a lightning strike, through to fine power protection, which eliminates the last voltage. one designed to protect the building structure and fabric and a second to protect sensitive equipment inside the building.

Read More
Requirements for cable tray usage in computer room

Requirements for cable tray usage in computer room

Learn NEC Article 392 requirements for cable trays, including grounding, bonding, fill capacity, and compliant installation for power, control, Ethernet, and. The International Electrotechnical Commission (IEC) provides detailed guidelines for cable tray systems under IEC 61537. IST will give design advice as to where the point of connection should be, and recommend a pathway for the new conduit or tray. maintain spacing or to keep cables in place when the tray is ect the minimum bend ra-dius for cables as they exit the bottom of the cable tray. A rung spacing of 6 to 9 inches (150 to 230 mm) is preferable when the cable tray cont d for instrumentation and control applications that require. To comply with code requirements and ensure system safety, metallic trays must be electrically continuous, properly bonded at all splice points, and securely connected to the building's grounding system. The mechanical and electrical characteristics, tests, certifications, overall quality management, recommendations mentioned in this technical guide only apply to our own cable management ranges and cannot under any circumstances be transposed to si osure, overheating or.

Read More
Modular computer room cold aisle principle

Modular computer room cold aisle principle

Containment systems work by enclosing either the cold aisle or the hot aisle between rows of server racks. Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing of hot and cold air stands out as a method that can dramatically reduce energy costs, minimize hot spots and improve the carbon footprint of data. Cold aisle containment (CAC) serves as a fundamental airflow management strategy in modern Data Centres, optimising cooling efficiency and enhancing overall performance. At Profile IT Solutions, we specialize in designing and implementing custom aisle containment solutions for data centers and server rooms.

Read More
Safety Technical Disclosure for Small Busbars in Computer Rooms

Safety Technical Disclosure for Small Busbars in Computer Rooms

Adequate spacing prevents short circuits and enhances system safety: Bare copper busbars: Minimum clearance ≥20mm to avoid phase-to-phase or phase-to-ground faults. Insulated busbars: Insulation allows for reduced clearance but must meet IEC 60664or UL 746Cdielectric strength. A manufacturer of electrical automation panels is not required to use a certified busbar system or to subject it to short-circuit tests, provided that it complies with Table G3. Since 1989 the standard for Industrial Control Equipment, UL 508 had been the primary industry standard to which components are certified in the U. Procedure: UV Test according to ISO 4892 – 2 method A; 1000 cycles of 5 min of watering and 25 min. The value of temperature and humidity for the test are (65±3)oC and (65±5) %. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert. Refer test certificates on 3 Ratings @690V and @800V are applicable for functional unit compartments w h Techno Module doors.

Read More