PRECISION COLD HEADING

Cold aisle wall-mounted type for broadcast transmission equipment rooms

Cold aisle wall-mounted type for broadcast transmission equipment rooms

Cold Aisle Containment or CAC is a proven, relatively easy to deploy solution for effectively managing airflow within a data centre. A CAC system surrounds the cold aisle and it keeps cold supply air separate from hot server exhaust air. Ardmac have developed a range of Ground Supported (GS) and Ceiling Supported (CS) assemblies catering to an array of different modular clean rooms and off-site construction industry requirements including data centre design and data centre construction. An enormous amount of energy is used every day to maintain an acceptable intake temperature to the IT equipment. This buying guide will help you understand the features of an aisle containment system, learn the important questions to ask before selecting a solution and compare different types of aisle containment kits.

Read More
Fiber optic cold connectors are prone to breakage

Fiber optic cold connectors are prone to breakage

Accumulation of ice and snow on aerial fiber optic cables can add weight and cause sagging or tension, potentially leading to physical damage or breakage. These cables, composed of thin strands of glass or plastic, transmit data as light signals, ensuring rapid and efficient communication. There are three common types of fiber connectors: SC, ST (bayonet-twist) and LC (push-pull locking). The LC connector is most commonly chosen, because it is much smaller than the other two, and also provides a secure clip connection. The fiber connection is UV resistant, salt spray resistant and sealed to IP66, IP68 and IP69K, while still providing an industry-standard LC interface as specified by IEC 61754-20. Fiber optic cabling problems with extreme cold happen when water finds its way into the ducts housing the cables.

Read More
Fiber optic cold connector shows red light but no signal

Fiber optic cold connector shows red light but no signal

Fibers that are bent too tightly will experience loss due to the light escaping the core. Fiber optic networks are celebrated for their speed and reliability, but even the best systems can encounter problems. When issues like signal loss, slow speeds, or intermittent connectivity arise, systematic troubleshooting is key. Below are some of the most common fiber optic issues and how to diagnose and fix them. Or it could be caused by the quality of the connector itself, such as poor end-face geometry that doesn't pass the parameters defined by IEC PAS 61755-3 standards, including angle of the.

Read More

Get In Touch

Connect With Us

📱

Spain Office (HQ)

+34 936 214 587

🇪🇺

EU Technical Center

+49 89 452 38 217

📍

Headquarters (Spain)

Calle de la Tecnología 47, 08840 Viladecans, Barcelona, Spain