CUSTOM SWITCHGEAR AMP RETROFITS PHOENIX ELECTRIC CORP.

Switchgear Wiring

Switchgear Wiring

The first models were very primitive: all components were simply fixed to a wall. This led to a further improvement, because the switching and measuring devices could be attached to the front, while the wiring was on the back.

Read More
Busbar type in low-voltage switchgear

Busbar type in low-voltage switchgear

In Busbars in LV Switchgear Panels, the busbar is the low-resistance conductor that takes power from the incomer and distributes it to outgoing functional units or feeders. IEC 61439 is a standard developed by the International Electrotechnical Commission (IEC) that covers design verification for low-voltage electrical products and assemblies. Busbars are the main current-carrying conductors inside a low voltage switchboard, and they strongly influence thermal performance, fault withstand, maintenance safety, and panel footprint. The IEC standard for busbar sizing provides detailed guidelines to help engineers select appropriate busbar.

Read More
Inter-voltage switchgear relay protection

Inter-voltage switchgear relay protection

This article provides an in-depth examination of the most common protective relay functions—ANSI device numbers 50, 51, 50N, 51N, 27, 59, and 86—and explains how they interlock within MV panel architectures. Protective relays and devices have been developed over 100 years ago to provide "lastline"of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. This guide is written for engineers, EPC teams, and procurement managers who need clear equipment decisions, RFQ details, and commissioning checks. Yes, these two systems are crucial in terms of safety because they protect not only the operator and other substation personnel but also the equipment in the. In fact, somebelieve that MV circuit breakers operate by themselves, without direct initiation by protective relays.

Read More
Busbar switchgear parameters

Busbar switchgear parameters

These standards specify the parameters that should be considered when sizing busbars, including current rating, short-circuit withstand capacity, temperature rise, insulation, and environmental conditions. The current rating is calculated from the conductor cross-sectional area, material (copper or aluminium), and maximum. For busbar sizing, the primary references are IEC 61439 (for low-voltage switchgear and controlgear assemblies) and IEC 60287 (for current-carrying capacity of cables). In this article, we will explain the five most important MV switchgear parameters. This guide is written for engineers, EPC teams, and procurement managers who need clear equipment decisions, RFQ details, and commissioning checks.

Read More