CUSTOM COMPUTER ENCLOSURES

Add lightning protection to the power distribution box in the computer room

Add lightning protection to the power distribution box in the computer room

The power distribution box of the computer room should be equipped with SPD (anti-electromagnetic surge) protection devices to prevent the power supply of the computer room from being cut off due to electromagnetic pulses caused by lightning strikes. Our light-ning and surge voltage protection systems are per-fectly matched to one another and to the requirements in the different zones – from the air-termination device, which must arrest the full energy of a lightning strike, through to fine power protection, which eliminates the last voltage. one designed to protect the building structure and fabric and a second to protect sensitive equipment inside the building.

Read More
Cold Aisle Computer Room Design

Cold Aisle Computer Room Design

The hot aisle /cold aisle data center layout was originated by IBM in 1992 and it is one of the oldest ways to save energy in the data center. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. Why should the computer room design hot and cold aisles, design principles and how to construct? Why should the computer room design hot and cold aisles? Because the computer room uses the hot aisle and cold aisle to change the previous practice of placing the cabinets in the same direction in the. Efficient airflow management in data centers relies heavily on proper Hot Aisle and Cold Aisle configurations.

Read More
Safety Technical Disclosure for Small Busbars in Computer Rooms

Safety Technical Disclosure for Small Busbars in Computer Rooms

Adequate spacing prevents short circuits and enhances system safety: Bare copper busbars: Minimum clearance ≥20mm to avoid phase-to-phase or phase-to-ground faults. Insulated busbars: Insulation allows for reduced clearance but must meet IEC 60664or UL 746Cdielectric strength. A manufacturer of electrical automation panels is not required to use a certified busbar system or to subject it to short-circuit tests, provided that it complies with Table G3. Since 1989 the standard for Industrial Control Equipment, UL 508 had been the primary industry standard to which components are certified in the U. Procedure: UV Test according to ISO 4892 – 2 method A; 1000 cycles of 5 min of watering and 25 min. The value of temperature and humidity for the test are (65±3)oC and (65±5) %. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert. Refer test certificates on 3 Ratings @690V and @800V are applicable for functional unit compartments w h Techno Module doors.

Read More