COLD AMP FREEZER ROOMS

Cold aisle wall-mounted type for broadcast transmission equipment rooms

Cold aisle wall-mounted type for broadcast transmission equipment rooms

Cold Aisle Containment or CAC is a proven, relatively easy to deploy solution for effectively managing airflow within a data centre. A CAC system surrounds the cold aisle and it keeps cold supply air separate from hot server exhaust air. Ardmac have developed a range of Ground Supported (GS) and Ceiling Supported (CS) assemblies catering to an array of different modular clean rooms and off-site construction industry requirements including data centre design and data centre construction. An enormous amount of energy is used every day to maintain an acceptable intake temperature to the IT equipment. This buying guide will help you understand the features of an aisle containment system, learn the important questions to ask before selecting a solution and compare different types of aisle containment kits.

Read More
Optical Cable Cold Bending Experiment

Optical Cable Cold Bending Experiment

IEC 60794-1-111: 2023 defines the test procedure to determine the ability of an optical fibre cable to withstand bending around a test mandrel. Cable Cold Bending Test is a test method used to evaluate the flexibility and cold resistance of cables at low temperatures. The NASA STI program provides access to the NASA Aeronautics and Space Database and its public interface, the NASA Technical Reports Server, thus providing one of the largest collections of aeronautical and space science STI in the world. The cable is bent around a small diameter mandrel a specific number of times at a specific low temperature and then inspected for any signs of damage or cracking.

Read More
Modular computer room cold aisle principle

Modular computer room cold aisle principle

Containment systems work by enclosing either the cold aisle or the hot aisle between rows of server racks. Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing of hot and cold air stands out as a method that can dramatically reduce energy costs, minimize hot spots and improve the carbon footprint of data. Cold aisle containment (CAC) serves as a fundamental airflow management strategy in modern Data Centres, optimising cooling efficiency and enhancing overall performance. At Profile IT Solutions, we specialize in designing and implementing custom aisle containment solutions for data centers and server rooms.

Read More