BS 5852 is a fire test method developed by the British Standards Institution (BSI) that assesses the ignitability and flame spread characteristics of upholstered furniture and related materials. Whether a headboard must meet the upholstery standard or the wall lining standard depends on how it is constructed and installed, and on the interpretation of the fire officer or building control officer responsible for the project. This Technical Information Sheet defines the requirements for headboards on trailers used to transport British Steel products. They can form an integral part of a load restraint system if the product is blocked directly against them. Comprehensive online training content that boosts employee safety and business success.

Read More
Power Plant Relay Protection Testing Procedure

Power Plant Relay Protection Testing Procedure

One approach to test the total protection system is to use primary injection techniques (see appendix H) that trigger protective relays and lockout relay, trip circuit breakers, and initiate annunciations and indications. Protective circuit functional testing, including lockout relay testing, must take place immediately upon installation, every 2 years thereafter, and upon any change in wiring. If applicable, documentation is required detailing how verified protection segments overlap to ensure there is not a gap. But failure to operate as intended can result in extensive damage, extended power outages, and loss of life.

Read More
Relay protection testing is divided into three types

Relay protection testing is divided into three types

Protective relay testing is usually divided into three categories: acceptance testing, commissioning, and maintenance testing. Acceptance or evaluation testing determines whether a relay is appropriate for use on a specific protection application within a power system. This guide explores the different types of protection relays and their testing procedures, with a focus on tools like secondary injection test sets and three-phase relay test sets. Distance Relays: Measure impedance to detect faults in transmission lines, aiding in fault location and isolation. There is generally a good deal of co-operation between electricity boards and relay.

Read More